A question about:
Relay Box for Windlass / 2/4-pole
Marilyn J.
on Jan 6, 2021
Can this control box be mounted upside down, or do the solenoids require the 4 connection terminals are facing upwards?
I ask because when I have the control box in my hand and gently shake it up and down, I hear a clunk noise inside, suggesting a part within the control box is moving when no power is applied. Is this normal to hear a rattle inside the box when it is shaken?
Thanks
Marilyn J. answered
on Oct 12, 2022
I learned from Lofrans that this box cannot be mounted upside down - the connection terminals must be facing upwards.
When we had it mounted facing downwards, operating the windlass would trip the breaker the second time the control was actuated. First time usually worked.
Once we altered our mount bracket so the control box could be remounted with connection terminals facing upwards, the box works fine.