ARGO FET Battery Isolator / MOSFET / 200A / 3 battery banks
Olaf E.
on Jul 2, 2020
Hi, I have a question related to changing from passive diode battery isolator to ARGOFET 200-3 in my 2007 BV 37CR. I have installed two different ARGOFET 200-3 this week, and i experience with both a 1,3 -1,8V leakage btw input and outputs. When turning off the main switch for the starter battery, it causes Alarm 1,4V for in the Panel 301. I have now changed back to the old passive diode, and everything is just fine.
I know there are other BV owners with the same experience, but they just ignore this alarm.
Hopefully some of you Bavaria guys have a good solution solving this issue ?
Answers:
Try W. answered
on Jul 7, 2020
Hello Olaf, I don't know how the alarm function of your Bavaria switchboard works. But from a lossless electronic charging distributor I would not expect any leakage voltage between outputs and input. I have already installed similar charging distributors from Mastervolt and Quick in my vehicles and never noticed leakage voltages between outputs and input. SVB has them with 2 or 3 outputs, article numbers #48400#, #48401#, #76504# and #76505#. I experimented a bit with all of them and at the input (without a connected charging source) I could only measure the battery voltage when I applied a positive voltage to the "IG" contact, and that was perfectly ok. Victron material is inexpensive and so far I thought it is good and inexpensive. But it seems to be true that once you buy cheap, you buy twice.
Olaf E. answered
on Jul 8, 2020
Thank you so much for sharing your experience. If I decide to replace my passive diode, I will choose Quick 220A-3.