SIEMENS Shore Connection Unit with Arc Fault Detection Device (AFDD) and Circuit Breaker (RCD/RCCB)
Article Number
52909
Description
Shore connection unit with fire protection breaker
Product details
Never been seen before!
Protection for cables, operators and against fire in a 230 V shore power unit.
This unit provides total protection in case of residual current, short circuits and overloads, as well as arcs which can occur in 230 V installations with loose terminal/plug connections, cable breaks or insulation damage, or with defective connection lines.
Common installations with RCDs and RCCBs cannot detect possible arcs in defective electrical equipment and it is statistically proven that arcs in electrical systems are among the most frequent causes of fire.
CAUTION:
When connecting the device, pay particular attention to the position of the L and N connections, which is only guaranteed with proper CEE plug connections. A Schuko plug connection or lengthening the feed cable is not permitted and should be avoided. Always make sure the L1 and N phase position is correctly connected and does not change, this must be permanently monitored. If you cannot guarantee this, the reverse polarity protected version should be used.
If you sleep on board your boat or caravan, and at the same time run chargers, fan heaters or cooling devices, you should use this innovative and compact shore power unit for an all-round safe AC power supply and to avoid possible fires caused by electrical equipment in the on-board AC network!
Small but nice!
The combination of a compact SIEMENS RCD/RCCB breaker and innovative AFDD fire circuit-breaker only requires the space of 2 dividing units, 1 dividing unit = 17.5-18 mm) in a small distribution box.
Residual Current Device / Circuit Breaker (RCD/RCCB)
The integrated SIEMENS residual current circuit breaker ensures the required personal protection for residual currents > 30 mA and short-circuit and overload protection for currents of 16 A. It works exactly the same as previous (RCD/RCCB) switches, but takes up considerably less space.
Fire Protection Breaker (AFDD)
The integrated SIEMENS fire protection breaker (Arc Fault Detection Device, or AFDD for short) first detects dangerous electric fault arcs, such as those that can occur at serial line damage points, i.e.. non-secure contacts such as loose screw or plug contacts. These faults are not detected by the RCD/RCCB breaker!
The AFDD also detects arcs that can occur as a result of insulation faults between active conductors or against the protective conductor.
In both cases, the circuit is quickly and reliably broken, preventing electrically ignited fires.
Insulation faults occur on board, for example, due to vibrations, thermal expansion and shrinkage, mechanical stress, corrosion and ageing.
Plastic housing (small distribution box or overload protector box) with transparent door
Grey surface mounted housing (RAL 7035), waterproof to IP65 with DIN rail, suitable for 3 dividing units, four rear mounting holes with a diameter of 5.5 mm. Dimensions (H x W x D): 96 x 100 x 150 mm.
Protection for cables, operators and against fire in a 230 V shore power unit.
This unit provides total protection in case of residual current, short circuits and overloads, as well as arcs which can occur in 230 V installations with loose terminal/plug connections, cable breaks or insulation damage, or with defective connection lines.
Common installations with RCDs and RCCBs cannot detect possible arcs in defective electrical equipment and it is statistically proven that arcs in electrical systems are among the most frequent causes of fire.
CAUTION:
When connecting the device, pay particular attention to the position of the L and N connections, which is only guaranteed with proper CEE plug connections. A Schuko plug connection or lengthening the feed cable is not permitted and should be avoided. Always make sure the L1 and N phase position is correctly connected and does not change, this must be permanently monitored. If you cannot guarantee this, the reverse polarity protected version should be used.
If you sleep on board your boat or caravan, and at the same time run chargers, fan heaters or cooling devices, you should use this innovative and compact shore power unit for an all-round safe AC power supply and to avoid possible fires caused by electrical equipment in the on-board AC network!
Small but nice!
The combination of a compact SIEMENS RCD/RCCB breaker and innovative AFDD fire circuit-breaker only requires the space of 2 dividing units, 1 dividing unit = 17.5-18 mm) in a small distribution box.
Residual Current Device / Circuit Breaker (RCD/RCCB)
The integrated SIEMENS residual current circuit breaker ensures the required personal protection for residual currents > 30 mA and short-circuit and overload protection for currents of 16 A. It works exactly the same as previous (RCD/RCCB) switches, but takes up considerably less space.
Fire Protection Breaker (AFDD)
The integrated SIEMENS fire protection breaker (Arc Fault Detection Device, or AFDD for short) first detects dangerous electric fault arcs, such as those that can occur at serial line damage points, i.e.. non-secure contacts such as loose screw or plug contacts. These faults are not detected by the RCD/RCCB breaker!
The AFDD also detects arcs that can occur as a result of insulation faults between active conductors or against the protective conductor.
In both cases, the circuit is quickly and reliably broken, preventing electrically ignited fires.
Insulation faults occur on board, for example, due to vibrations, thermal expansion and shrinkage, mechanical stress, corrosion and ageing.
Plastic housing (small distribution box or overload protector box) with transparent door
Grey surface mounted housing (RAL 7035), waterproof to IP65 with DIN rail, suitable for 3 dividing units, four rear mounting holes with a diameter of 5.5 mm. Dimensions (H x W x D): 96 x 100 x 150 mm.
Documents
Datasheet
PDF, 326,88 KB
Datasheet
PDF, 372,82 KB
Brochure
PDF, 367,32 KB
Datasheet
PDF, 376,47 KB
Datasheet
PDF, 327,62 KB
Datasheet
PDF, 327,19 KB
Datasheet
PDF, 506,02 KB
Datasheet
PDF, 327,75 KB
Datasheet
PDF, 373,86 KB
Datasheet
PDF, 373,32 KB
Datasheet
PDF, 326,84 KB
Manual
PDF, 1,11 MB
Manual
PDF, 3,37 MB
Customers also bought
Stainless Steel Hose Clamps
from
€1
76
18 variants
TRUDESIGN
Hose Connector
from
€2
61
6 variants
Wood Thru-Hull Plugs / Ø 10-40 mm
only
€6
68
> 100
JOCKEL
Fire Blanket 100 x 100 cm
only
€25
17
44
-10%
YACHTCARE
LEAK HERO Sealant / 625 ml
€33.45
only
€30
21
> 100
Stainless Steel Pipes V4A
from
€14
24
4 variants
LED long-light / 10-30 V / 10 W
only
€25
17
21
Similar items
PHILIPPI
Onboard System / Shore Panel Indicator Panel LAR
only
€33
57
22
SIEMENS
Shore Power Unit with Arc Fault Detection Device (AFDD) and Residual current operated Circuit-Breaker with Overcurrent protection (RCBO)
only
€294
08
5
SIEMENS
Shore Power Connection Unit / 30 mA
only
€78
07
13
PHILIPPI
LAE 113 Shore Connection Unit
only
€323
49
4
BAVARIA
AC Distributor with Inverter Input 230 V
only
€537
77
1
BAVARIA
AC Distributer EN-Base Module 230 V
only
€323
49
1
BAVARIA
Shore Power Supply Panel
only
€470
55
2
PHILIPPI
Shore Power Connection Unit LAE 100 / LAE 110
only
€189
03
4
Customers ask customers
Ask other SVB customers who have already purchased this product from us about their experience.
Your question will be automatically forwarded to other SVB customers and published on the product page. Please do not ask any questions which can only be answered by the SVB team – such as the status of an order or product availability. You are also more than welcome to contact our SVB team by email at: info@svb24.com or by phone on: +49 (0)421 57290510 .
No questions asked yet. Be the first to ask a question!