Hot Water Boiler
Connecting your hot water boiler to the engine: When installing a hot-water boiler on board, the 220-volt power supply should be additionally equipped with an FI personal protection machine and an isolation transformer.
Heating Element 800 W / 220 V

-8%
Magnesium Anode for B3, BX and BXS Series Boilers

QUICK
Magnesium Anode for B3, BX and BXS Series Boilers
13.95
EUR
only €13.95
Heating Element for 24 - 75 l / 750W/220V

ISOTEMP
Heating Element for 24 - 75 l / 750W/220V
39.95
EUR
only €39.95
Heating Element 16 l 750W/220V

-6%
Heating Element for older models (orange) 750W/220V

ISOTHERM
Heating Element for older models (orange) 750W/220V
59.95
EUR
only €59.95
Hot Water Boiler
SVB recommends that you secure your unit with a 10 amp / 220 volt fuse. The current-carrying cable should consist of a braided 2.5 mm² cable, which is not only guided through the bilge but also installed in such a way that the cable won't break under vibration.
The hot water boiler is connected via a bypass to the internal cooling circuit of the motor boat. Heat-resistant hoses should be used, so that they are not damaged by the temperature of the cooling water. In the main line between the bypass entry and exit, a reduction valve is to be used to regulate the amount of current going through the hot water heater. It is recommended that the hose is installed in a such a manner that it enters the heat exchanger of the hot water heater before the drain valve. In the event that servicing or repair of the heat exchanger is needed, it can be easily emptied. Make sure that the cooling water temperature does not exceed 85°C. If this should be the case, a mixing valve must be installed. The mixing valve works automatically. You just have to turn the knob in order to reach temperatures between 38 and 65°C with a tolerance of +/- 7 degrees. Reliability is ensured with this device. The thermostat measures the temperature and adjusts itself, depending on the supply of hot and cold water.
The hot water boiler is connected via a bypass to the internal cooling circuit of the motor boat. Heat-resistant hoses should be used, so that they are not damaged by the temperature of the cooling water. In the main line between the bypass entry and exit, a reduction valve is to be used to regulate the amount of current going through the hot water heater. It is recommended that the hose is installed in a such a manner that it enters the heat exchanger of the hot water heater before the drain valve. In the event that servicing or repair of the heat exchanger is needed, it can be easily emptied. Make sure that the cooling water temperature does not exceed 85°C. If this should be the case, a mixing valve must be installed. The mixing valve works automatically. You just have to turn the knob in order to reach temperatures between 38 and 65°C with a tolerance of +/- 7 degrees. Reliability is ensured with this device. The thermostat measures the temperature and adjusts itself, depending on the supply of hot and cold water.